If you've had an insulation quote in Boca Raton, there's a good chance it was for blown-in insulation. It's the workhorse of South Florida attics: loose fiberglass or cellulose fed through a hose from a truck in the driveway and spread evenly across the attic floor. It fills around wiring, plumbing and truss webs where batts leave gaps, and it gets more R-value into an existing attic for less money than anything else.
Here's what it costs in Boca, how fiberglass and cellulose compare, how deep it needs to be, and how to make sure the job is done right.
When blown-in is the right choice
Blown-in fits most Boca Raton attics: vented, trussed attics over a finished drywall ceiling with reasonable access through a hatch. That covers the bulk of the city's 1970s–1990s single-family homes and many villas. The Department of Energy's guide to insulation types describes loose fill the same way — it's built for retrofits and attics where other insulation is hard to install.
It's not the right answer for every house. If the air handler and ducts are in the attic and you want them inside the conditioned envelope, or the roof is low-slope with almost no attic space, spray foam on the roof deck is usually better — see our spray foam cost guide for Boca Raton. For open framing in an addition or remodel, batts are often simpler.
Fiberglass vs. cellulose

Both are blown loose, both are proven, and both get you to R-38. The differences that matter in Boca:
- Depth. Cellulose packs about R-3.5 per inch, so R-38 is roughly 11 inches. Fiberglass needs about 15. In tight attics near the eaves, cellulose fits more R-value.
- Weight. Cellulose is several times heavier at the same R-value. On older ceilings we check the drywall before loading it.
- Water. Fiberglass doesn't absorb water and dries quickly. Cellulose soaks up a roof leak and holds it. With Boca's tile roofs and storm seasons, that's why fiberglass is our default.
- Pests and fire. Cellulose is treated with borates for fire and pest resistance. Fiberglass is inherently non-combustible.
We go deeper in blown-in cellulose vs. fiberglass.
What blown-in insulation costs in Boca Raton
- Blown fiberglass to R-38: $1.10–$1.90 per sq ft
- Blown cellulose to R-38: $1.30–$2.10 per sq ft
- Air sealing the ceiling plane: $0.30–$0.60 per sq ft
- Removal of old insulation, when needed: $1.00–$2.00 per sq ft
A 2,000 square foot attic usually lands at $2,200 to $4,500 for a sealed R-38 top-up. Price swings come from how much is already there, attic access, how many recessed lights and penetrations need sealing, and whether anything has to come out first.
Homes starting below R-8 may qualify for FPL's instant $220 rebate when the work is done by an FPL Participating Independent Contractor — see FPL's ceiling insulation rebate page.
How a blown-in job works
- Inspection. Depth measured in several places, photos of the eaves, ducts, wiring and any water or rodent signs.
- Prep. Drop cloths from the door to the hatch. Recessed lights that aren't rated for contact get covers or are sealed per manufacturer guidance.
- Air sealing. Top plates, plumbing and wire holes, duct boots and the hatch are sealed. See why air sealing comes first.
- Baffles. Installed at the eaves so insulation can't block the soffit vents.
- Blowing. Material is fed from the truck and spread to an even depth, with extra attention to the thin eaves.
- Markers and paperwork. Depth rulers stapled to trusses and a certificate showing material, R-value and bag count.

How to verify the job
Under the FTC R-Value Rule, professional installers must give you R-value information based on standard tests. In practice, ask for the material, target R-value, installed thickness, square footage and number of bags on your invoice. Then check the math against the manufacturer's coverage chart, and look at the depth markers yourself. Under-blowing — fluffing material to look deep while using fewer bags — is the most common shortcut in this trade, and the bag count is how you catch it.
Ready for a quote? See blown-in insulation in Boca Raton, our blown-in insulation service page, and attic insulation in Boca Raton for the bigger picture.
Frequently asked questions
How much does blown-in insulation cost in Boca Raton?
Blown fiberglass to R-38 typically costs $1.10 to $1.90 per square foot installed and blown cellulose $1.30 to $2.10. For a 2,000 square foot Boca Raton attic that is roughly $2,200 to $4,500 including air sealing and baffles.
How many inches of blown-in insulation do I need for R-38?
About 15 inches of blown fiberglass or about 11 inches of cellulose. The exact settled depth is printed on the manufacturer's bag coverage chart, and that chart is what your installer should follow.
Is fiberglass or cellulose better for Boca Raton?
Both work. Fiberglass is lighter, does not absorb water and is our default for most Boca attics. Cellulose packs more R-value per inch and resists air movement a little better, but it is heavier and slower to dry after a roof leak.
How long does blown-in insulation take to install?
A top-up on a typical Boca Raton home usually takes a few hours. With air sealing and baffles it is often a single day. If old insulation has to be removed first, plan on a full day or two.
Header photos: Pexels (free license). Job photos: Standard Insulation projects from our Google Business Profile. Tables by Standard Insulation.