Most Boca Raton homes built before 2000 have attic insulation that was installed to the code of its day — often R-19 — and has settled to 3 to 5 inches since. That's roughly R-11 to R-14, less than half of today's minimum. So the real question isn't just "how much do I need?" but "how much do I have, and how far short is it?"
The number: R-30 minimum, R-38 target
Under the Florida Building Code, Energy Conservation (8th Edition), Palm Beach County is in Climate Zone 1, where attic ceilings need at least R-30. We install R-38 to allow for settling and the thin spots at the eaves. ENERGY STAR's recommended R-values land in the same range, and the code itself is maintained by the Florida Building Commission. For the code details, see Florida attic R-value requirements.
What that means in inches
R-value per inch varies by material, so the same R-38 is a different depth for each:

These are approximate. The FTC R-Value Rule requires every bag of loose-fill to carry a coverage chart listing the minimum settled thickness and the number of bags per 1,000 square feet for each R-value. A good contractor installs to that chart and leaves a signed certificate in the attic.
How to check your own attic
- Open the hatch on a cool morning — Boca attics are dangerous on summer afternoons.
- Without stepping off the framing, push a ruler straight down through the insulation until it touches the ceiling drywall.
- Measure in three or four spots away from the eaves, where it's always thinner.
- Look for bare spots, matted or stained insulation, and areas pushed aside by AC or cable work.

Rough guide for fiberglass: under 6 inches is well below code; under about 3 inches is likely below R-8, which matters for the rebate.
Topping up vs. starting over
If the existing insulation is dry and clean, we usually air seal and blow new insulation over it to bring the total to R-38. If it's wet, moldy, contaminated by rodents or badly compressed, it comes out first — see insulation removal in Boca Raton and attic mold removal. Blown fiberglass to R-38 typically runs $1.10–$1.90 per square foot; see blown-in insulation in Boca Raton.
The FPL rebate
If your existing insulation is below R-8 and the work is done by an FPL Participating Independent Contractor, FPL's ceiling insulation rebate page explains the $220 instant rebate. See how the FPL insulation rebate works.
More isn't always better
Beyond R-38 to R-49, each extra inch saves less. Insulation also must not block the soffit vents. In most Boca homes, sealing the ceiling, the ducts and the attic hatch pays back more than going deeper. The Department of Energy's guide to where to insulate covers the other places worth insulating.
We measure every attic before we quote it, and we leave depth rulers and a certificate when we finish. See our attic insulation service or insulation in Boca Raton.
Frequently asked questions
How much attic insulation do I need in Boca Raton?
The Florida Building Code, Energy Conservation (8th Edition) puts Palm Beach County in Climate Zone 1, with an R-30 minimum for attic ceilings. We recommend R-38, which is roughly 14 to 16 inches of blown fiberglass or 10 to 11 inches of cellulose.
How many inches of insulation is R-38?
It depends on the material. Roughly 14 to 16 inches for blown fiberglass, 10 to 11 inches for blown cellulose and 10 to 12 inches for fiberglass batts. The manufacturer’s coverage chart on the bag gives the exact settled depth.
How do I check how much insulation is in my attic?
From the attic hatch, push a ruler straight down through the insulation to the ceiling drywall in several spots, away from the eaves. Under about 6 inches of fiberglass means the attic is well below code; under about 3 inches may qualify for the FPL rebate.
Can you have too much attic insulation?
Beyond about R-38 to R-49 the extra savings get small, and insulation must never block soffit vents. Air sealing and duct sealing usually pay back more than going deeper.