Palm Beach County is our primary service area, and it has one of the most varied building stocks in Florida. A 1953 CBS bungalow in Northwood, a 1985 tract home in Greenacres, an oceanfront estate in Manalapan, and a 2022 build in Westlake are four completely different insulation problems.
Here's how we think about the county.
The older coastal core: West Palm Beach, Lake Worth Beach, Lake Park
Housing stock here runs from the 1920s through the 1960s. Predominantly CBS — concrete block and stucco — with wood furring strips and plaster or drywall on the interior. Attics are frequently low-slope, hard to access, and originally insulated with whatever was standard at the time, which frequently means very little.
What we find: Attic insulation at R-8 to R-13, often original. Nothing in the walls. Extensive air leakage at top plates and around old plumbing. Frequently, ductwork retrofitted into an attic that was never designed to hold it.
What works: Air seal aggressively, blown-in to R-38, and a radiant barrier if the ducts are up there. For homes being renovated, Fi-Foil in the furring cavity while the walls are open.
The suburban belt: Boynton Beach, Greenacres, Royal Palm Beach, Wellington
Mostly 1975–2000 construction. Concrete block, trussed attics with reasonable access, ducts almost universally in the attic, and original blown fiberglass that has now settled well below its installed depth.
What we find: R-19 installed in 1988, measuring R-11 to R-14 today. Perimeter areas nearly bare because the original crew couldn't reach past the trusses. Twenty to forty recessed can lights, none of them airtight. Duct boots unsealed at the ceiling.
What works: This is the classic Florida retrofit. Air seal, baffle the soffits, top up to R-38, radiant barrier over the duct runs. Typical project $3,500–$6,000 and homeowners consistently report it as the best money they've spent on the house.
The coastal high-end: Palm Beach, Manalapan, Gulf Stream, Highland Beach, Jupiter Inlet Colony
Larger homes, more complex roof geometry, frequently multi-level with cathedral ceilings and limited attic volume. Often elevated or with substantial glazing. Salt exposure is severe.
What we find: Complicated assemblies where the thermal boundary is ambiguous, cathedral ceilings with inadequate cavity insulation, and unconditioned spaces buried inside the envelope.
What works: Closed-cell spray foam roof deck encapsulation is frequently the right answer, because it resolves the boundary ambiguity by putting everything inside. Elevated homes also need underfloor treatment — closed-cell foam on the underside of the floor system handles insulation, air sealing, and moisture in one pass and stands up to salt air far better than batt in netting.
The northern communities: Jupiter, Palm Beach Gardens, Tequesta, Juno Beach, North Palm Beach
A wide mix — 1970s and 80s coastal construction alongside substantial newer development. Ducts in attics is common in the older stock; newer builds increasingly have mechanical in conditioned space.
What works: Depends heavily on the specific house, which is why the free assessment matters. Where ducts are in the attic, the standard air-seal-plus-R-38-plus-radiant-barrier package. Where they're not, straightforward blown-in top-up captures most of the value at much lower cost.
The newer western communities: Westlake, Loxahatchee Groves, The Acreage
Post-2005 construction meets a meaningfully stricter energy code, so baseline insulation is generally adequate. The opportunities here are different.
What we find: Code-minimum R-30, sometimes installed unevenly. Blower-door-tested envelopes that passed but not by much. Ducts sometimes in attics, sometimes in chases.
What works: Marginal top-up from R-30 to R-38 is cheap since the setup is the whole cost. Duct sealing frequently produces more benefit than more insulation. An energy audit is worth doing before spending, because the obvious answer is often not the right one in newer homes.
The Glades: Belle Glade, Pahokee, South Bay
Entirely different work. Agricultural and light industrial buildings, packing houses, metal structures, and older residential stock with limited prior investment.
What works: Metal building systems — banded liner or closed-cell foam on the panel underside, both for heat and for the condensation that destroys stored product. Residential work is straightforward blown-in and air sealing, often on homes that have never had either done properly.
Code notes for Palm Beach County
Palm Beach County is Climate Zone 1 — R-30 attic minimum. It is not in the High-Velocity Hurricane Zone, which covers only Miami-Dade and Broward, but it is in a wind-borne debris region with substantial design pressure requirements.
Permitting for insulation varies by municipality. Simple attic top-ups usually don't require one; spray foam roof deck applications, work altering the thermal envelope during a permitted renovation, and all commercial work generally do. We handle permitting where it's required and meet the inspector.
Getting started
The free assessment takes about 45 minutes. We measure depth in multiple locations, check for moisture and rodent evidence, look at duct condition and location, photograph everything, and give you a written scope with options priced side by side — whether or not you hire us.